AI 040
Analog Input
- 4 analog inputs with IEPE interface
- Signal conversion in frequency range of 31 mHz to 20 kHz (16 bits)
- Max. sampling rate 50 kSPS
- 5 µs offset between channels
- Condition Monitoring
For the S-DIAS system, EPLAN Macros are available for simple integration into the control cabinet.
Technical data
Performance data
Supply voltage
+24 V DC (+18-30 V DC)
IEPEs
Type
IEPE interface
Amount
4
Measuring range
±0.172 ... ±5.5 V AC
Conversion rate/channel
≥ 5 µs (adjustable, default setting 5 µs)
Data recording/channel
maximum 64 Word
Short-circuit proof
Yes
Cable break monitoring
Yes
Hardware filter
typically 31 MHz (high pass 1st order), typically 20 kHz (low pass 3rd order)
Software bandpass filters
Lower cut-off frequency
adjustable (minimum 0.1 Hz)
Upper cut-off frequency
adjustable (maximum 10 kHz)
Processed measured values/cycle
configurable
Output parameters
Average Value, Minimum Value, Timestamp, Minimum Value, Timestamp, Maximum Value
Sensor supplies
Adjustable current levels
0, 4, 8, 12 mA individually adjustable for each channel
Supply voltage
+18-30 V DC
Sensor voltage
typically 19.1 V DC
Mechanical properties
Width (mm)
12,5
Height (mm)
104
Depth (mm)
72
Protection type
IP20
Article number / Certification
Item number
20-009-040
Standardization / Certification
UL 508 (E247993)